// JOB RA38027 SPRI 3.8.27 APAR RA38027 * SPRI 3.8.27, Issued by GSS on May 06, 2003 * Revised October 29, 2003 * Status=TESTED Type=REQUIRED * ------------------------------------------------------------------- * Problem: Correct JOB/SEQ number processing * Correct JOB/SEQ number processing. This is the SPRI 3.8 version of RA37187 * ------------------------------------------------------------------- * Conditions for applying APAR: * The phases affected by this APAR normally are loaded resident * in the processing region during activation. This allows the * APAR to be applied at any time, however its effect will not be * experienced until the product is reactivated. // PAUSE *** Enter CANCEL to bypass APAR. Press ENTER to apply. // LIBDEF CL,TO=IJSYSRS,FROM=IJSYSRS (target lib) MVT/VSE systems only. // DEFINE GETVIS=200K MVT/VSE systems only. // EXEC MSHP,SIZE=900K CORRECT 1975-38-SPR:RA38027 /* 1975-SPR-01-038:RA38027 for VSE/SP */ AFFECTS PHASE=SPRISS$A ALTER 47 1B:FF AFFECTS PHASE=SPRIJELR ALTER 2D8 9610A02B : 9620C011 ALTER 2DC 9640A02B9620 : D207A02C3988 ALTER 2E2 C011D207 : 47F03902 ALTER 902 39023904 : 9150A02B /* JOB ALREADY?*/ ALTER 906 39063908 : 47703912 /* YES */ ALTER 90A 390A390C : 9650A02B /* SET JOB FLGS */ ALTER 90E 390E3910 : 47F032EA ALTER 912 39123914 : 4870A036 ALTER 916 39163918 : 9650A02B ALTER 91A 391A391C : 47F032F0 AFFECTS PHASE=SPRIRJOB ALTER 2E 9610A02B : 47F0355A ALTER 55A 355A355C : 9150A02B ALTER 55E 355E3560 : 4780356A ALTER 562 35623564 : 4870A036 ALTER 566 35663568 : 47F0303C ALTER 56A 356A356C : 9610A02B ALTER 56E 356E3570 : 47F03032 /* /&