// JOB MA95348 MVT 9.5.348 APAR MA95348 * MVT 9.5.348, Issued by PRP on July 12, 2005 * Status=TESTED Type=REQUIRED * ------------------------------------------------------------------- * Problem: BSIMOUNT cancelled with msg 0V03I - more than 255 PFIXes * For GETVIS requests with the PFIX=YES option, an error in $NAM * results in the failure to decrement the page(s) PFIX counter * when the area is released (FREEVIS). This can result in a * pages PFIX counter reaching the limit of 255 and jobs * cancelling with the 0V03I message. * * This APAR resolves the problem reported as call 199678. * * * * * * ------------------------------------------------------------------- * Conditions for applying APAR: * This APAR may be applied at any time, however its effect will * not be experienced until the next time the system is IPL'ed. // PAUSE *** Enter CANCEL to bypass APAR. Press ENTER to apply. // LIBDEF CL,TO=IJSYSRS,FROM=IJSYSRS (target lib) MVT/VSE systems only. // DEFINE GETVIS=200K MVT/VSE systems only. // EXEC MSHP,SIZE=900K CORRECT 1975-95-MVT:MA95348 /* 1975-MVT-01-095:MA95348 for VSE/SP */ AFFECTS PHASE=MVTVSE$A ALTER 188 6C:FF AFFECTS PHASE=$NAM /* FIX AT PFXFRE12+X'08' */ ALTER 167A 8120 : 8118 /* APFRESUB */ /* /&