// JOB JA39017 PLF 3.9.17 APAR JA39017 * PLF 3.9.17, Issued by PRP on October 29, 2004 * Status=TESTED Type=REQUIRED * ------------------------------------------------------------------- * Problem: FFB Hardwait with POWER and PLF STMTPOOL * This APAR corrects a problem where PLF may cause a FFB * Hardwait on VSE/ESA 2.3 and later systems with POWER if the * PLF STMTPOOL option is used. * * This APAR resolves the problem reported in InfoSys 7452 and * also in call 182485. * ------------------------------------------------------------------- * Conditions for applying APAR: * This APAR may be applied at any time, however its effect will * not be experienced until the next time the system is IPL'ed. // PAUSE *** Enter CANCEL to bypass APAR. Press ENTER to apply. // LIBDEF CL,TO=IJSYSRS,FROM=IJSYSRS (target lib) MVT/VSE systems only. // DEFINE GETVIS=200K MVT/VSE systems only. // EXEC MSHP,SIZE=900K CORRECT 1975-39-PLF:JA39017 /* 1975-PLF-01-039:JA39017 for VSE/SP */ AFFECTS PHASE=SPIPLF$A ALTER 3D 11:FF AFFECTS PHASE=SPIPLFRT /* FIX AT SVC0220+X'06' */ ALTER 702A 47209076 : 4720914E /* BNP PAT1 */ ALTER 7116 44008008 : 92040243 /*PAT1 MVI RID+1,REENTRID */ ALTER 711A 07F60000 : 47F09076 /* B SVC0244 */ /* /&