// JOB GA72247 DOCS 7.2.247 APAR GA72247 * DOCS 7.2.247, Issued by PRP on June 24, 2003 * Revised August 08, 2003 * Status=TESTED Type=REQUIRED * ------------------------------------------------------------------- * Problem: Let ENTER key refresh ?a display and update interval. * DOCS APARs GA72221 and GA72236 corrected problems with the * Question A (?A) command but also changed the behavior of the * command if the ENTER was used to refresh the display. This * APAR restores the original behavior of the ENTER key when used * in an active ?A display. * * This APAR resolves the problems described in Info/Sys 8082 and * 8122. * ------------------------------------------------------------------- * Conditions for applying APAR: * This APAR may be applied at any time, however its effect will * not be experienced until the next time the system is IPL'ed. // PAUSE *** Enter CANCEL to bypass APAR. Press ENTER to apply. // LIBDEF CL,TO=IJSYSRS,FROM=IJSYSRS (target lib) MVT/VSE systems only. // DEFINE GETVIS=200K MVT/VSE systems only. // EXEC MSHP,SIZE=900K CORRECT 1975-72-DOC:GA72247 /* 1975-DOC-01-072:GA72247 for VSE/SP */ AFFECTS PHASE=DOCS$A ALTER 123 07:FF AFFECTS PHASE=DOCSMAIN /* FIX AT READ61+X'44' */ ALTER 36BA D50179C9A2BB : D50179C997FC /* CLC DEVID,BLANKS */ ALTER 36C0 4780BB3C : 4780BB2E /* BE READ62 */ /* /&